Tempered glass is heat-treated for strength and breaks into small, rounded pieces. Laminated glass bonds two or more panes around a plastic interlayer that holds the pieces together after impact. Both count as safety glazing in BC. Which one you specify depends on location, risk, noise, security and budget.
This guide is written for property managers, landlords, strata councils, retail and restaurant owners and business tenants in Metro Vancouver. It covers how the choice gets made on a real commercial project: what the BC Building Code expects, where each type belongs, what drives cost in CAD, and how glazing fits into permits and a schedule when the building is occupied.
TL;DR
- Tempered glass is the baseline for storefront doors, sidelights and many interior partitions. It is stronger than regular glass and breaks harmlessly, but it falls out of the frame in pieces when it fails.
- Laminated glass stays in the frame after breakage. It suits overhead glazing, mezzanine and stair guards, break-in resistance and noise control.
- Both can meet the BC Building Code’s safety glazing requirements, so the right choice is set by the specific location, not by a general preference.
- Laminated usually costs more. One Ontario glazing firm puts the premium at roughly 40% to 60% over plain tempered for the same opening, so confirm local quotes early.
- Tempered glass cannot be cut or drilled after tempering. Final dimensions, notches and holes must be locked before ordering.
Table of Contents
- How the two glass types differ
- What the BC Building Code asks for
- Where tempered glass is the right call
- Where laminated glass earns its cost
- Cost in CAD and what drives it
- Permits, engineering and schedule in Metro Vancouver
- Installing glass in an occupied building
- Our perspective: decide opening by opening
- Working with Multigroup on glazing scope
- A short checklist before you specify glass
- FAQ
- Sources
How the two glass types differ
Tempered glass is annealed glass that has been heated and rapidly cooled. According to one commercial glass supplier, the process makes it 4 to 5 times stronger than regular glass, and it breaks into small pieces rather than sharp shards. Laminated glass is built differently: two or more panes with a PVB interlayer between them that keeps fragments attached if the glass cracks.
The practical difference shows up after failure. A tempered lite that breaks usually lets go of the whole opening. A laminated lite cracks but stays put, so the opening remains closed and people below or beside it are protected from falling pieces.
Practitioners also stress that “safety glass” is a performance designation. Both types qualify, but they serve different risk profiles: tempered for strength and harmless breakage, laminated for containment and security. Treating them as interchangeable is the common mistake.
| Tempered | Laminated | |
|---|---|---|
| Construction | Single heat-treated pane (or a unit of them) | Two or more panes bonded with a PVB interlayer |
| When it breaks | Small, rounded pieces; the opening can empty | Cracks but stays in the frame |
| Best known for | Strength, impact resistance at doors and sidelights | Containment, security, sound control, overhead safety |
| Field changes | None after tempering | Depends on fabrication; confirm with the glazier |
| Relative cost | Baseline | Higher, because of the interlayer process |
What the BC Building Code asks for
The BC Building Code requires safety glazing in hazardous locations such as transparent doors, sidelights and guards. Provincial guidance on windows, doors and skylights notes that laminated or tempered glass conforming to CAN/CGSB-12.1 satisfies this, and that the 2024 code continues to reference those standards.
The same guidance treats laminated glass as a design consideration for windows near exterior door locks, to discourage forced entry, though it is not mandatory in that location. That distinction matters for retail and restaurant owners: code compliance is the floor, and security is a separate decision you make with your insurer and landlord.
For glass guards, the standard is similar. A summary of BC railing rules states that guard glass can be laminated or tempered safety glass to CAN/CGSB-12.1-M90, and that panels must be free of chips and cracks. Frameless systems, where the glass is the structural member, require professional engineering on every project because the glass must resist the full design load, not just the frame. That is also why glass guards cost more than framed systems.
A caution: code summaries from suppliers are a starting point. The authority having jurisdiction, your municipality’s plan reviewer and your engineer or architect of record, decides what applies to your drawings.

Where tempered glass is the right call
Tempered glass is the right choice where people are likely to bump or strike the glass and where a fall-out hazard overhead is not a concern. It is the standard option for several common commercial locations.
- Storefront doors and sidelights. Tempered glass is a standard choice here because human impact is likely.
- Interior partitions in offices and clinics. Glass meeting rooms and reception screens at floor level are typical tempered applications.
- Framed guards at modest heights where the engineer is comfortable with the system and the risk profile.
- Budget-sensitive openings where there is no overhead exposure, no security requirement and no acoustic target.
The constraint is fabrication. Tempered glass cannot be cut, drilled or edge-worked after tempering, so every dimension, notch and hole must be final before the glass goes into the furnace. A wrong field measurement means a full remake, with the lead time that implies. On a tenant improvement this is the single most common way glazing delays a handover.
Our practice is to verify openings after framing and rough-in, then release glass orders against measured dimensions, not drawings alone.

Where laminated glass earns its cost
Laminated glass earns its premium where breakage must not leave an opening, or where something other than strength is the goal. In commercial tenant improvements, it is often preferred overhead, in skylights and in high-fall-risk areas such as elevated mezzanines or balconies, because the interlayer retains fragments and limits fallout into occupied spaces below.
Consider laminated for:
- Skylights and overhead glazing, particularly above lobbies, corridors and retail floors that stay open during the work.
- Mezzanine and stair guards in warehouse conversions and multi-level retail, where a failure could mean a fall.
- Storefront windows near door hardware, where break-in resistance is worth buying.
- Acoustic control, such as clinic consulting rooms or offices facing a busy street. Laminated units are often specified for this reason.
- Lobby and common-area glass in strata and multi-unit buildings, where residents pass beneath or beside the glazing daily.
It is worth being direct about security. Tempered glass is a safety product, not a security barrier, in the words of that Ontario glazier. A laminated lite can still be broken, but it takes longer and leaves no clear opening. Whether that is worth the price depends on your inventory, your insurance terms and your neighbourhood.
Cost in CAD and what drives it
Laminated costs more because of the extra fabrication. The premium varies by thickness, interlayer, size and supplier, so treat any single percentage as a planning figure. The Ontario firm cited above estimates laminated at about 40% to 60% more than plain tempered for the same opening. That is not a Vancouver quote, and you should ask for local pricing.
At facade scale, industry observers report Canadian glass facade projects averaging CAD 150 to CAD 300 per square foot, with high-performance laminated units, often needed for acoustic control or overhead safety, pushing costs toward the upper end. For a typical storefront or office TI, the glass is a smaller share of the budget, but it can swing the total through four things:
- Glass type and thickness. Laminated, acoustic or larger lites cost more.
- Engineering. Frameless guards and structural glazing need engineered drawings, which add fees and time.
- Lead time. Custom tempered and laminated units are made to order. A late change means a remake.
- Access and protection. Installing heavy glass in an occupied building means protected routes, after-hours windows and sometimes a lift or hoist.
A useful approach for budgeting: carry glass as a separate line with an allowance, and ask the GC to price both tempered and laminated for any opening where you are unsure. Our commercial interiors upgrade guide explains how we structure scope and allowances so a late glazing decision does not reopen the whole budget.
Permits, engineering and schedule in Metro Vancouver
In Metro Vancouver, new storefronts, curtain walls and structural glazing generally need a building permit, and the application must show BC Building Code compliance. Plan reviews for commercial permits typically take 2 to 4 weeks, with added engineering for glass railings on decks higher than 1,800 mm or in multi-family and commercial buildings.
That timing source describes typical cases. Your municipality, whether Vancouver, Burnaby, Surrey, North Vancouver, Coquitlam, New Westminster or Langley, sets its own intake and review times, and complex files take longer.
What this means for your glazing decision:
- Decide glass types before drawings are submitted. A change after permit issuance can mean a revision and another review.
- Flag engineered items early. Frameless guards, structural glazing and large openings need stamped drawings.
- Schedule glass last among long-lead items you can still measure. Order from field dimensions once framing is complete.
- Plan the install separately from the permit. Inspection sign-offs and occupancy conditions can depend on guards and doors being in place.
If you want the permit mechanics in more depth, our guides on building permits for Canadian property owners and the Vancouver permitting checklist walk through the steps.
Installing glass in an occupied building
Glass work in an occupied building is a sequencing problem as much as a product problem. Tempered and laminated lites are heavy, awkward to move and unforgiving of poor handling, so the route from the loading area to the opening has to be planned, protected and, usually, closed to the public while the glass is in motion.
On occupied sites we typically plan for:
- After-hours or phased installs for lobbies, atriums and storefronts so tenants and customers are not routed around hoisting.
- Temporary protection such as hoarding, floor protection and signed detours for elevators and common corridors.
- Overhead isolation below any skylight or high glazing work.
- Clear communication with the property manager, strata council or neighbouring tenants about dates and noise.
As a prime contractor on site, we also carry the WorkSafeBC prime contractor duties, which matters when several trades and a glazier share a floor. Bringing glazing under the same schedule as electrical, framing and finishes avoids the common failure where the glass arrives and the opening is not ready, or the opening is ready and the glass is three weeks out.
An outline of how a glazing item runs on a typical commercial fit-out:
- Confirm glass type per opening against code, engineer’s direction and the lease or strata bylaw.
- Include the glass in the permit drawings.
- Frame the openings and measure in the field.
- Release the order with final dimensions, notches and hardware cut-outs.
- Protect the route, install after hours if needed, and seal.
- Inspect, clean and close out with the building’s requirements.
Our perspective: decide opening by opening
We see glass decisions go wrong in two directions. Owners over-specify laminated across a whole space because it sounds safer, then discover the budget is gone. Or a team defaults to tempered everywhere and has to revisit a mezzanine guard or skylight after plan review. Neither comes from bad intent. Both come from deciding by glass type instead of by opening.
Our approach is a short glazing schedule early in scoping. Each opening gets a line: location, who passes by, what is below or beside it, whether it is overhead, any security or noise goal, and which code provision applies. Where two options are plausible, we price both so you decide with real numbers.
We self-perform and manage the whole project, which means one accountable contractor handles the permit drawings, the order timing, the install window and the inspection. For property managers that is the point: fixed scope, a clear schedule and fewer hand-offs in a building that stays open.
Our rule of thumb: tempered where people touch the glass and nothing falls on anyone if it fails, laminated where something or someone is above, below or on the wrong side of it.
— MultigroupTeam
Working with Multigroup on glazing scope
Glazing is part of many of the projects we deliver: storefronts and entries in retail buildouts, partitions and reception glass in tenant improvements, guards and openings in warehouse renovations, and entry upgrades in café and restaurant renovations. For lobby and common-area work, see our 100 Park Royal lobby renovation.
We are a licensed and insured Vancouver commercial GC with $5M liability coverage and WorkSafeBC coverage, and we manage municipal permits and BC Building Code compliance. If you have a space where glass is in question, tell us about the project and we will include a glazing schedule in the scope.
A short checklist before you specify glass
- List every glazed opening by location and note what is overhead, below and beside it.
- Check the lease and strata bylaws for landlord requirements on storefronts, lobby glass and building-standard finishes.
- Ask your insurer whether laminated storefront glazing affects your terms.
- Confirm engineering needs for frameless guards, large lites or structural glazing.
- Lock dimensions before tempering and keep a change-control date in the schedule.
- Ask for both prices on any opening where the choice is open.
- Plan the install window with the property manager, including route protection and noise.
FAQ
Is laminated or tempered glass more expensive?
Laminated is generally more expensive because of the interlayer fabrication. One Ontario glazing firm estimates a 40% to 60% premium over plain tempered for the same opening. Actual Vancouver pricing depends on size, thickness and supplier, so request quotes for both.
What type of glass is recommended for skylights?
Laminated is usually preferred for overhead glazing because the interlayer retains fragments if the glass breaks, reducing fallout into the space below. Your engineer or architect confirms the exact build-up for the project.
Is tempered glass safety glass under the BC Building Code?
Yes, when it conforms to CAN/CGSB-12.1. Provincial guidance accepts laminated or tempered safety glass in hazardous locations such as doors, sidelights and guards. Always confirm the requirement for your specific opening with your design professional.
Can tempered glass be cut to fit on site?
No. It cannot be cut, drilled or edge-worked after tempering. Dimensions must be final before fabrication, which is why we measure in the field after framing.
Do I need a permit to replace storefront glass?
New storefronts, curtain walls and structural glazing generally need a building permit in Metro Vancouver. Like-for-like replacement may be treated differently by each municipality, so check with the local building department or your GC before ordering.
Sources
- Commercial Glass Types Explained: Tempered, Laminated
- FB33-11 (2017) Use of Laminated Glass in Glass Railing Systems
- BC Building Code bulletin B24-04: windows, doors and skylights
- British Columbia Building Code for Glass Railings
- BC Building Code Railing Height guide
- Build with Light (glass.org)
- Etobicoke Storefronts: Tempered vs Laminated for Security
- Glass facades: project costs, material selection, labor
- Commercial Tenant Improvement Permit Process BC